Photometer with Bluetooth® Technology
Applications of Lovibond Reagents »
Reagents for Photometry »
Reagents also suitable for use in Hach® (Disclaimer) devices »
Highlights
|
Delivery Content
|
Data Transfer
The photometer MD 110 has integrated Bluetooth® functionality. The app AquaLX® is the ideal supplement to the Lovibond® photometer. Measurement results are transmitted via the Bluetooth® interface for fast evaluation or administration on smartphones or tablets. All data can be handled and allocated immediately, on-site. The app displays all results in a clear graphic with min. and max. values and supports the export of the data as an Excel® compatible CSV file. For further information, please refer to www.lovibond.com/bluetooth.
The MD 110 uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparency sample chamber. The units supply accurate, reproducible results very quickly. Other major advantages include ease of operation, ergonomic design, compact dimensions and safe handling.
The calibration and software-based adjustment options mean that the MD 110 is also suitable for use as a testing instrument. The tests are conducted using either Lovibond tablet reagents with long-term stability and a guaranteed minimum 5 or 10 year shelf life, VARIO powder reagents or using liquid reagents.
Scroll Memory (SM)
To avoid unnecessary scrolling for the required test method, the instrument memorizes the last method used before switching off the instrument. When the instrument is switched on again, the scroll list comes up with the last used test method first.
Calibration certificateBeside the “Certificate of Compliance” which is supplied with the MD 110, calibration certificates are available at cost on request. Calibration certificates are individually supplied per instrument and per method. The Calibration Certificate has to be ordered together with the new instrument and cannot be delivered at a later stage. |
N.I.S.T TraceabilityThe instrument has a factory calibration, which is related to international standards which are not N.I.S.T traceable. The instrument may be calibrated by the user in a „user calibration mode“ with N.I.S.T traceable standards. (N.I.S.T. = National Institute of Standards and Technology) |
Optics | LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters: 430 nm ∆ λ = 5 nm 530 nm ∆ λ = 5 nm 560 nm ∆ λ = 5 nm 580 nm ∆ λ = 5 nm 610 nm ∆ λ = 6 nm 660 nm ∆ λ = 5 nm |
Wavelength Accuracy | ± 1 nm |
Photometric Accuracy 4) | 3% FS (T = 20°C – 25°C) |
Photometric Resolution | 0.01 A |
Power Supply | 4 micro batteries (AAA), capacity approx. 17 hours or aprox. 5000 tests In continuous operation with the display lighting switched off |
Auto – OFF | automatic switch-off |
Display | backlit LCD (on keypress) |
Storage | internal ring memory for 125 data sets |
Interface | Bluetooth®-interface for test data transfer |
Additional feature | real time clock and date |
Calibration | factory calibration and user calibration. Reset to factory calibration possible |
Dimensions | 155 x 75 x 35 mm (L x B x H) |
Weight | basic unit approx. 260 g |
Environmental conditions | temperature: 5 – 40 °C rel. humidity: 30 – 90 % (non condensing) |
Approval | CE |
4) tested with standard solutions
3in1
Test | Code |
---|---|
MD 110 Chlorine, pH, Cyanuric Acid tablet reagents 0.01 – 6.0 mg/l Cl2 / 0,1 – 10 mg/l Cl2* 6.5 – 8.4 pH ; 0 – 160 mg/l cyanuric acid |
29 80 102 |
MD 110 Chlor, pH, Cyanursäure, liquid reagent for chlorine and pH 0.02 – 4 mg/l Cl2 / 6.5 – 8.4 pH 0 – 160 mg/l cyanuric acid |
29 80 152 |
4in1
Test | Code |
---|---|
MD 110 Chlorine,pH, Cyanuric Acid tablet reagents 0.02 – 6.0 mg/l Cl2 / 0,1 – 10 mg/l Cl2* 6.5 – 8.4 pH ; 0 – 160 mg/l Cyanursäure 5 – 200 mg/l CaCO3 (TA) |
29 80 702 |
MD 110 Chlorine, pH, Cyanuric Acid, Alkalinity-M (total) Flüssigreagenzien für Chlor und pH 0.02 – 4 mg/l Cl2 / 6.5 – 8.4 pH 0 – 160 mg/l cyanuric acid / 5 – 200 mg/l CaCO3 (TA) |
29 80 752 |
6in1
Test | Code |
---|---|
CMD 110 Chlorine, Bromine, pH, Cyanursäure, Alkalinity-M (total), Calcium hardness tablet reagents 0.02 – 6.0 mg/l Cl2 / 0,1 – 10 mg/l Cl2* 0.05 – 13 mg/l Br ; 6.5 – 8.4 pH 0 – 160 mg/l cyanuric acid ; 5 – 200 mg/l CaCO3 (TA) 0 – 500 mg/l CaCO3 (CaH) |
29 80 902 |
* Delivery without reagents for measuring range 0.1 – 10 mg/l Cl 2
Item | Code |
---|---|
Set of 12 round vials with lid Height 48 mm, Ø 24 mm | 19 76 20 |
Set of 5 round vials with lid Height 48 mm, Ø 24 mm | 19 76 29 |
Set of 12 plastic vials (PC), with lid “Multi”-Type 2, Ø 10 mm |
19 76 00 |
Vial stand for 6 round vials Ø 24 mm, acrylic glass | 41 89 51 |
Cleaning cloth for vials | 19 76 35 |
4 micro batteries (AAA) | 19 50 026 |
Measuring beaker, volume 100 ml | 38 48 01 |
Plastic stirring rod, 13 cm length | 36 41 00 |
Plastic stirring rod, 13 cm length, (10 pc.) | 36 41 20 |
Plastic stirring rod, 10 cm length | 36 41 09 |
Plastic stirring rod, 10 cm length, (10 pc.) | 36 41 30 |
The Bluetooth® word mark is a registered trademark owned by Bluetooth SIG, Inc. and any use by Lovibond® Tintometer GmbH is under license. IOS® is a registered trademark of Cisco, Inc. and licensed to Apple, Inc. AndroidTM is a trademark of Google, Inc.