SD 300 pH, SD 320 Con

Waterproof Hand-held Meters for pH/Redox/Temperature Conductivity, TDS, Salinity, Temperature

Highlights

  • Rugged, water resistant (IP 67) designed for field use
  • PC interface (USB / serial or analog)
  • Automatic buffer detection (SD 300 pH)
  • Data logger and alarm function (min./max.)
  • Good Laboratory Practice (GLP-features)
    Clear, concise result reading:
    easy-to-read backlit LCD display
  • Automatic temperature compensation
    High resolution
    (0.001 pH / 0.1 mV) (SD 300 pH)
  • Dirt-insensitive up-to-date 4-pole conductivity cell offering highest precision (SD 320 Con)

Applications

  • Drinking Water
  • Cooling/Boiler Water
  • Waste Water
  • Pool Water
  • Surface Water

Features SD 300 pH

Min / Max Value Memory highest and lowest measured value is saved.
Auto Hold freeze and display measurement.
Auto Power Off if unused, the meter automatically switches off after a selected period (0 to 120 min, or deactivated)
Additional Display for pH Electrode and Battery Bar graph display
Low Battery Display “BAT” Automatic Temperature Compensation
Automatic Temperature Compensation (ATC) in pH mode (in the range of 0 – 105 °C) when the temperature probe is connected. Temperature can be input manually, when the temperature probe is not attached.
pH Calibration Automatic Buffer Recognition. Permissible electrodes’ data: Asymmetry: ±55mV/Slope:45…62mV/pH The condition of pH Electrode is checked at each calibration. 1, 2 or 3 point calibration with Lovibond® Standard Buffer, DIN 19266 Buffer or any manually entered Buffer values.
Redox Measurement (ORP) 2 options: “mV” Standard Redox or mV measurement „mVH” Conversion to hydrogen systems according to DIN38404 Part 6
rH Measurement The rH value is calculated from a measured Redox value and a manually input pH value

Delivery Content

Order Code: 724600 SD 300 pH without electrode, with batteries, protective armouring, instruction manual, guarantee sheet

Order Code: 724610 SD 300 pH (SET 1) instrument, batteries, pH/temp. plastic-electrode type 230, pH-buffer-set (pH 4.00/7.00/10.00), in case, manual, guarantee sheet

Order Code: 724611 SD 300 pH (SET 2) as SET1, but with pH / temperature plastic-electrode type 225, temperature sensor Pt1000, manual, guarantee sheet

Assessories

Order code Article
721231 pH/temp.-electrode
type 231 plastic/gel/temperature NTC30kOhm (SET 1)
721226 pH-electrode
plastic/gel-type 226 (SET 2)
721235BNC pH-electrode glass/gel-type 235
721240BNC Redox-electrode plastic-type 240
72 12 45 Pt1000 Temperature sensor (SET 2)
41 86 09 KClsolution, 3 molar saturated
with AgCl, 100 ml
72 12 47 pH buffer solution 4,00 (25 °C) red, 90 ml
72 12 48 pH buffer solution 7,00 (25 °C) yellow, 90 ml
72 12 49 pH buffer solution 10,00 (25 °C) blue, 90 ml
72 12 50 pH buffer-set 4.00/7.00/10.00 (25°C)
72 12 52 pH buffer 4.00 (25°C) 1 litre
72 12 54 pH buffer 7.00 (25°C) 1 litre
72 12 56 pH buffer 10.00 (25°C) 1 litre
19 50 70 Redox calibration solution,
470 mV, 100 ml
72 46 20 USB 300 cable,
for connection to a computer
72 46 25 GSOFT 3050 data transmission
software with logger for setting,
reading and printing of stored data
72 50 60 Case with foam inlet

Measuring ranges

pH – 2,000 … 16,000 pH
Redox /mV – 2000,0 … 2000,0 mV
Temperature – 5,0 … + 150,0 °C
+ 23,0 … + 302,0 °F
rH 0,0 … 70,0 rH

Accuracy

pH ± 0,005 pH
Redox / mV ± 0,05 % FS (mV or mVH)
Temperature ± 0,2 °C (- 5,0 … + 100,0 °C)
rH ± 0,1 rH

Connections

pH, Redox BNC female connector, compatible to standard BNC plugs and waterproof BNC plugs, additional banana-jack (4 mm) for separate reference electrode input resistance: 1012 Ohm
Temperature 2 banana jacks (4 mm) for temperature probe (Pt1000 or NTC 10K)
Interface / Supply  4-pole bayonet connector for serial interface and supply (with accessory USB 300)
Display two 4.5 – digit seven-segment display (15 mm and 12 mm)

pH Calibration

Automatically 1, 2 or 3 point calibration, Lovibond® Standard Buffer or Buffer to DIN19266
Manually 1, 2 or 3 point calibration
Protection class IP67 (housing and connections)
Dimensions 160 x 86 x 37 mm (H x W x D) incl. protection cover
Weight 250 g incl. battery and protective armouring
Housing impact resistant PA 6 G B30 housing with pop-up clip
Power Supply

2 x AAA-battery (included) power consumption: < 1.0 mA

Battery life 1000 hours

Features SD 320 Con

Min / Max Value Memory highest and lowest measured value is saved

Auto Hold freeze and display measurement

Auto Power Off if unused, the meter automatically switches off after a selected period (0 to 120 min, or deactivated)

Low Battery Display “BAT”

Automatic temperature compensation As conductivity depends strongly on temperature, each conductivity value is only valid at the corresponding temperature. Therefore the device supports temperature compensation, i.e. referring the conductivity to a reference temperature (selectable: 20 °C or 25 °C).

Salinity measurement Salinity means the sum of amount of all dissolved salts in water. The unit is g / kg.

TDS measurement (total dissolved solids) TDS means the mass concentration of dissolved media in a liquid. The unit is mg/l.

Delivery Content

Order Code: 72 47 00 SD 320 Con (SET 1)
instrument, batteries, conductivity cell LC 12 (measuring range 0 – 200 mS), manual, guarantee sheet in case

Order Code: 72 47 20 SD 320 Con (SET 2) instrument, batteries, conductivity cell LC 16 (measuring range 0 – 1000 mS), manual, guarantee sheet in case

Order Code: 72 47 10 SD 320 Con (Set 3)
instrument, batteries, pure water electrode
(measuring range 0 – 100 mS/cm) manual, warranty information in case

Assessories

Order code Article
19805040 Conductivity cell LC 12,
measuring range 0 – 200 mS
19805040 Conductivity cell LC 16,
measuring range 0 – 1000 mS
72 22 50 Calibration solution 1413 µS/cm
72 46 20 USB 300 cable,
for connection to a computer
72 46 25 GSOFT 3050 data transmission
software with logger for setting,
reading and printing of stored data
72 50 60 Case with foam inlet

Measuring ranges

Number 5
Smallest range 0,000 … 5,000 μS / cm or 0,0 … 500,0 μS / cm **
biggest range 0 … 5000 μS / cm * or 0 … 1000 mS / cm **

Resistivity 

0.005 … 500.0 kOhm / cm (depends on cell constant)

TDS

0 … 5000 mg/l (depends on cell constant)

Salinity

0.0 … 70.0 (g salt / kg water equals PSU = Practical Salinity Unit)

Temperature

– 5.0 … + 100.0 °C, Pt1000 or NTC (10 kOhm)

Supported cell constants 

4,000 … 15,000 / cm-1 0,4000 … 1,5000 / cm-1 0,04000 … 0,15000 / cm-1 0,004000 … 0,015000 / cm-1

Accuracy

Conductivity 

± 0.5 % of reading
± 0.1 % FS (depends on electrode)

Temperature ± 0,2 °C (- 5,0 … + 100,0 °C)

Connection

Conductivity, Temperature 

1 x 7 pole bayonet connector for connection of different measuring cells

Supported temperature sensors 

Pt1000 or NTC (10k)
Interface / ext. supply 

4-pole bayonet connector for serial interface and supply (with accessory USB 300)

Display

two 4.5 – digit seven-segment display (15 mm and 12 mm)

Protectionclass 

IP67(housingandconnections)

Dimensions 

160x86x37mm(WxHxD) incl. protection cover

Weight   

250 g incl. battery and protective armouring

Housing

impact resistant PA 6 G B30 housing with pop-up clip

Power supply

2 x AAA-battery (included) power consumption: < 6,25 mA

Battery life  160 hours

depends on cell constant of used electrode
* cell constant 0.01 / cm
** cell constant 0.1 … 1.2 / cm